Co-generation- Technical Plus points |
by: Mr.A.P.Singh , |
| Introduction |
|
||
|
| |||
IMPROVEMENT IN PERFORMANCE OF BOILER As boiling house is always having fluctuating steam demand, which was maintained by operating PRDS of 1.0 Kg./Cm2, it gave at times an additional load of 10-15 TPH on boiler. By introducing the Co- generation, it has been observed that the makeup steam demand in boiling house reduces resulting in minimum operation of 1 Kg./Cm2 PRdS. Therefore the load on the boiler becomes comparatively more uniform. UNIFORM
STEAM PRESSURE TO PROCESS When back pressure turbine runs on fuel load of 9 MW exhaust of 1.2 ± 0.1 Kg./Cm2 are being maintained for boiling house, which resulted in steam consumption on cane at 45%, only 7 Kg./Cm2 line of PRDS is in use for melting of sulphur and drying of sugar.
|
|||||||
| |||||||